Zabbix MPA – Ruckus Wireless Access Point Monitoring

Ruckus Wireless Access Point Monitoring
(AP Standalone Monitoring via Zabbix)

This article will provide you with the necessary information to help monitor your Ruckus Wireless Access Points using the standard built in Zabbix SNMP Templates. Monitoring will be carried out in Zabbix Passive mode via SNMP.

Ruckus Access Point SNMP Setup

To enable SNMP on your Ruckus Wireless Access Point you can either log into the front end portal page or use the second option below using PUTTY
Use PUTTY if you don’t have access to the the front end SNMP option. Once you have enabled (SNMP) using the below method then move on to the Zabbix Front-End setup instructions listed further below to start monitoring.

Ruckus Wireless Access Point Model Used: Tested And Working
Ruckus Wireless Access Point 7363

Enable SNMP via PUTTY
Download PUTTY and then connect to your Ruckus Wireless Access Point via either a Terminal Session or SSH Session. You will then need to carry out the following commands listed below to setup and enable SNMP.

Ruckus Command Line Interface SNMP:

rkscli: set snmp
-> community ro <name> — read-only community name
-> community rw <name> — read-write community name
-> manager <ip> — SNMP manager IP addressrkscli: set snmp community ro PUBLICKEY
OK
rkscli: set snmp community rw PRIVATEKEY
OK
rkscli: set snmp manager ZabbixServerIP
OK

rkscli: get snmp
SNMP ro community : PublickKey
SNMP rw community : PrivateKey
SNMP Manager : Zabbix Server IP
OK

Command lines in (GREEN) change both [PublicKey] and [PrivateKey] to a word of your choice and also replace the “SNMP Manager” with your Zabbix IP Address. Once done, use the [get snmp] command to verify the details were set, then exit the command line interface and log into the Zabbix Front End portal.


Zabbix Front End Template Setup
(Template Setup Within Zabbix MPA)

Log into the Zabbix Front-End interface and create a [Host] with the following attributes below.

Hostname: Name Of Your Choice (OR) Hostname Of Device
SNMP Interface: IP Address Of Your Device / Port (161)

Template (Tab)
Select: Template Module Interfaces Simple SNMPv2

Macros (Tab)
Macro: {$SNMP_COMMUNITY}
Value: ” This Will Be Your Public Key, See Below, Call It What You Want”

Change Auto-Discovery Update Value For Template
(Template Module Interfaces Simple SNMPv2)

From 3600 (60 Minutes)
To 600 (10 Minutes) Or Less

I would personally recommended in-between  (1 to 5 Minutes) this will allow for faster response times when monitoring for customers. 

 

Leave a Reply